- Catalog item
- BK-ULP-8040MR-2
- Catalog output
- 10500 GPD (39.7 m³/d)
Catalog capacities are selection references. Final output, energy use and water quality depend on the confirmed feed water, operating conditions and supplied configuration.
Configuration & selection
Check pump operating range, actual salinity, temperature and required product-water quality together. The lower catalog test pressure is not a site energy-saving guarantee; a complete system projection is needed to compare operating duties.
Membrane specifications & test conditions
| Membrane model | ULP-8040MR-2 |
|---|---|
| Active membrane area | 440 ft² (40.9 m²) |
| Feed spacer | 28 mil |
| Permeate flow at test conditions | 10500 GPD (39.7 m³/d) |
| Stabilized salt rejection | 99.60% |
| Minimum salt rejection | 99.50% |
| Test pressure | 150 psi (1.03 MPa) |
| Test solution | 1500 mg/L NaCl |
| Test temperature | 25 °C |
| Test pH | 7.5–8.0 |
| Test recovery | 15% |
These are single-element catalog test values, not a guaranteed system output. Compare flow and rejection only with their stated pressure, feed solution, temperature and recovery. Confirm dimensions, connections and the system projection before replacement.
Specify the operating conditions
- Feed-water source, salinity, temperature and analysis
- Required permeate flow, quality and operating hours
- Existing model, dimensions, connectors and pressure vessel
- Element quantity, array layout and delivery destination
A matching model format or similar test flow does not establish interchangeability. Confirm mechanical fit and system performance before replacement.
Applications
From selection to installation
Request a proposal with the equipment list, process arrangement, utility requirements, delivery scope and maintenance access. Agree on commissioning responsibilities, consumables and spare parts before placing an order.
Other products in this series

BW-4040 — brackish water RO membrane
BK-BW-4040 · 2500 GPD (9.5 m³/d)
For brackish-water treatment and industrial water preparation. Compare the membrane area, test flow and salt rejection with your feed-water analysis and installed vessel arrangement.
View product ↗
BW-8040 — brackish water RO membrane
BK-BW-8040 · 10500 GPD (39.7 m³/d)
For brackish-water treatment and industrial water preparation. Compare the membrane area, test flow and salt rejection with your feed-water analysis and installed vessel arrangement.
View product ↗
BW-4040FR — fouling-resistant RO membrane
BK-BW-4040FR · 2000 GPD (7.6 m³/d)
A fouling-resistant membrane option for reuse-water and challenging feed-water enquiries. Its catalog uses a 34 mil spacer; selection still requires a pretreatment and cleaning review.
View product ↗
SW-4040 — seawater RO membrane
BK-C-SW-4040 · 1600 GPD (6.1 m³/d)
A seawater RO element with catalog performance stated under seawater-strength salt and boron test conditions. Evaluate the membrane together with the high-pressure system, intake pretreatment and product-water target.
View product ↗
SW-400 — seawater RO membrane
BK-C-SW-400 · 7500 GPD (28.4 m³/d)
A seawater RO element with catalog performance stated under seawater-strength salt and boron test conditions. Evaluate the membrane together with the high-pressure system, intake pretreatment and product-water target.
View product ↗